MAXIMUMALLOWABLE DUCTLENGTHS (IDF IDF ) DISCHARGE OUTLET Two 12“ducts One 16“duct LENGTH 24 Feet 45 Feet Flue size-6”on all units For the IDF HS, the maximum allowed ducting is 50' for the 12" X 2 and ' for the 16". MODEL IDFII IDF IDFHS MAXIMUM INPUT , BTU/HR , BTU/HR , BTU/HR NOZZLE SIZE · (2, kg) GENERATOR 8 KW AVR regulation FUEL SYSTEM Fuel Requirements: No. 1 fuel oil or blend HEATERS Fuel Consumption: Two (2) I.C.E. Frost Fighter OHV indirect Engine: GPH ( LPH) at full load* fired heating units, , BTU/HR* Heaters, each: , BTU gal. per hour ( per hour) Multiple heat outlets for a . Resetting the High Limit Switch on the Frost Fighter IDF If your IDF heater goes into lockout, there’s no need to panic. So, over here, you have a toggle, which is manual and thermostat. Right now, I’m going to run the unit in a manual set up.
Download Manuals Purveyors of the Finest Heaters Since BT Download BT Download HPL D7 Download BT NEX-D5 Download BTNEX-G2 Download Flameless M Download Flameless K Download BT-Blaze Turbo Download BT-Blaze Turbo Download Frost Fighter IDF OIL/DIESEL Download Frost Fighter IDF LP/NG Download Frost Fighter IDF OIL/DIESEL Download Frost Fighter. Frost Fighter one retainer bolt, washer, nut.: $ Frost Fighter Inner Small Cover Panel.: $ A Frost Fighter REAR LEG FOR 16" WHEEL IDF IDF $ A Frost Fighter /" Pneumatic Tire and Wheel Assembly with 1" axle bore 16" Total Diameter We are proud to feature brands like Frost Fighter in our online catalog of construction tools and equipment. Frost Fighter A FIRST Stage LP/NG Regulator RH-DGJ.. for OHV/IDF Models. Add to Cart. Frost Fighter Lifting Bail (IDF/ Series) $ Add to Cart. Frost Fighter A 3ft Flue Extension w/ 8" Rain Cap.
The range is usually between 90°F and °F. When the surrounding temperature is lower, the fan switch should be set higher. This will help the unit from cycling the main fan so often. So when the heat exchanger builds up enough heat to “make” the setting on the fan switch, the blower motor will have power and turn on. Frost Fighter Inc. warrants the Frostfighter heater to be free from defects in workmanship and materials for a period of twelve (12) months from date of initial service not to exceed fifteen (15) months from date of shipment. If during the warranty period, the heat exchanger fails under normal use and service due to a. and (IDF = 2) 1. Locate the adjustable damper connection on the right hand side when facing the burner. 2. Loosen the nut on the adjustable connection, and manually move the damper connection until the desired position is achieved (i.e. no pulsations and/or smoke from flue). 3. Re-tighten the nut on the adjustable damper connection.
0コメント